Hydraulic impact can descend the system stability and control precision, then the quality of sheared plates will be poor. So it is necessary to research it. A conclusion was gotten that shortening the length of pipes between pumps and servo valves could reduce the hydraulic impact by theoretical analysis. And its correctness was confirmed by simulation with AMESim software.