Aiming at the shortcomings of hydraulic AGC testing system, a new test method was designed based on the original testing system. Displacement sensor was replaced by the resistance strain gage as an improvement. Through the finite element simulation analysis and repeated static experiments, it is confirmed that the new method is feasible.