The design with calculation for specific structural parameters of solenoid valve was made and the AMESim simulation model for the shifting solenoid valve was established,on the basis of analyzed operating characteristics and principle of pilot shift solenoid valve of automatic transmission.The simulation results show that the pressure change curves with shifting solenoid valve designed are accord with the law of pressure in clutchs jointing process.The foundation of shift control for automatic transmission is laid through this study.